UT100C Handheld Capnograph ETCO2 Monitor are commonly used devices in clinics, hospitals and for first aid, emergency diagnostic and monitoring situations. They measure the patient's blood oxygen saturation (SpO2%) level and Pulse Rate, ETCO2 and RESP, vital indicators of many conditions/ health status
Technical Specification |
|||||
Enclosure |
|||||
Weight |
258grams (9.1 ounces) with batteries |
||||
Dimensions |
13.5cm × 7.5cm × 2.8cm |
||||
Alarms |
|||||
Categories |
Patient status and system status |
||||
Notification |
Audible and visual |
||||
Setting |
Full storage, low battery and sensor off |
||||
Range |
Pulse rate (30-350bpm), SpO2 (0-100%) |
||||
Alarm volume level |
0-85dB |
||||
Range, Accuracy and Resolution |
|||||
Range Type |
Range Values |
||||
Measurement Ranges |
|||||
SpO2 |
0-100% |
||||
Pulse rate |
30-350bpm |
||||
RESP |
0-150bpm |
||||
ETCO2 |
0-20% (0-150mmHg) |
||||
Measurement Accuracy |
|||||
SpO2 |
70-100% (±2%), <70% undefined |
||||
Pulse rate |
±2bpm/±2% take maximum |
||||
ETCO2 |
±2 mm Hg @ < 5.0% CO2 (at BTPS) < 10% of reading @ > 5.0% CO2(at BTPS) |
||||
RESP |
±1rpm |
||||
Resolution |
|||||
SpO2 |
1% |
||||
Pulse rate |
1bpm |
||||
ETCO2 |
0.1mmHg |
||||
RESP |
1rpm |
||||
Electrical |
|||||
AC power requirement |
100-240VA, 47-63Hz |
||||
Power comsumption |
20VA |
||||
Batteries |
|||||
Types |
Alkaline/Ni-Mh Batteries, IEC: LR6 |
||||
Operating time |
≥20hours without ETCO2;≤10hours with ETCO2 |
||||
Charge time |
≤ 6hours |
||||
Environment |
|||||
Operating tempearture |
0-45℃ |
||||
Storage temperature |
-20-60℃ |
||||
Operating humidity |
30-95% |
||||
Operating altitude |
-500-5000m |
||||
Trends |
|||||
Types |
Tabular |
||||
Memory |
Save total 120 hours data events. Save data and time, alarm conditions, pulse rate and SpO2 measurements |
||||
Standards and Certification |
|||||
IEC 62366 |
Medical devices-Application of usability engineering to medical devices |
||||
IEC 62304 |
Medical device-software life cycle processes |
||||
MDD 93/42/EEC |
European Medical Device Directive |
||||
ISO 13485 |
Medical equipment-Quality management system |
||||
EN ISO 14971 |
Medical devices-Risk management |
||||
EN 60601-1 |
Medical electrical equipment |
||||
EN 60601-2 |
Medical electrical equipment |
||||
EN 60601-8 |
Medical electrical equipment |
||||
EN 980 |
Symbols for use in labeling of medical devices |
||||
EN 1041 |
Information supplied by the manufacture of medical devices |
||||
ISO 80601-2-61 |
Medical electrical equipment-Particular requirements for the basic safety and essential performance of pulse oximeter equipment for medical use |
||||
EN ISO 10993-1 |
Biological evaluation of medical devices |
||||
EN ISO 10993-5 |
Biological evaluation of medical devices |
||||
EN ISO 10993-10 |
Biological evaluation of medical devices |
||||
ISO 14155-1 |
Clinical investigation of medical devices |
||||
CE |
CONFORMITE EUROPEENNE |
||||
SFDA |
State Food and Drug Administration |
Standard Configuration
Main unit 2 Years
Accessories 6 Months